172 × 150 × 51 mm nominal AC axial fan with iron impeller, dual ball bearings and 100–120 / 220–240 VAC options.

Technical overview

Fan family
AC Fan
Frame dimensions
172 × 150 × 51 mm
Rated voltage
100–120 / 220–240 VAC
Frequency
50 / 60 Hz

Typical applications

JA17251D — Typical applications
IndustryEquipment & application examples
Industrial control & power suppliesPLC and electrical cabinets, high-power inverters, servo drives, switching power supplies and UPS.
Automation, laser & weldingWelding machines, fiber-laser cutting and marking systems, reflow and wave soldering, ageing chambers and oven ventilation.
New energy & powerEnergy-storage cabinets, photovoltaic inverters, charging equipment and power-conversion enclosures.
Telecom & server cabinetsCommunication cabinets, server racks, base-station power cabinets and machine-room equipment ventilation.
Instruments & environmental testingLarge environmental and temperature-test chambers, analytical instruments and high-power laboratory test equipment.
Commercial equipment & air purificationIndustrial air-purification units, large self-service kiosks, HVAC control cabinets and LED display enclosures.
Rail transit & industrial machineryOn-board electrical cabinets, construction-machinery control boxes and heavy-duty industrial cabinets.

JA17251D / DATASHEET

Technical data

Original model codes from the PDF are retained below for traceability.

The PDF heading gives nominal dimensions of 172 × 150 × 51 mm, while its drawing shows 172 ±0.5 × 152 ±0.5 × 51 ±0.5 mm. The performance table and curve also show different static-pressure limits. Both are reproduced as supplied; confirm dimensions and performance before selection.

Frame
Aluminum alloy, painted black
Impeller
Iron
Bearing
Dual ball bearing
Motor
Shaded-pole induction motor
Protection
Impedance protection
Weight
1000 g
Lead wire (optional)
UL1015 AWG #22
Life expectancy
50,000 h (25 °C, 65% RH)

Performance by model

Values separated by / correspond to 50 / 60 Hz respectively. Airflow and static pressure are separate test limits, not a single operating point.

Source modelBearingVoltage (VAC)Frequency (Hz)Current (A)Power (W)Speed (RPM)Airflow (CFM)Static pressure (mmH₂O)Noise dB(A)Weight (g)
JA17251HB1(D)Dual ball100–12050/600.50/0.4728/362600/2800169/18210.9/7.150/521000
JA17251HB2(D)Dual ball220–24050/600.28/0.2534/282600/2800169/18210.9/7.150/521000